1. APPLICATION AND FEATURES
Permanent Magnetic Lifters Model PMQZQ
is mainly used for connecting instructions during lifting
and handling operation. They can hoist moving iron block,
cylindrical and other magnetic material. They are easy
for operation, safe in handling, lightly and ingeniously
structured. Hence they are widely used as hoisting devices
in factories, docks warehouses and transportation industries.
By using them, you can improve your working conditions
and increase your working efficiency.
2. CONSTRUCTION AND SPECIFICATION
2.1
Construction: MODEL PMQZQ Permanent Magnet Lifter has
strong magnetic path produced by NDFEB magnetic materials.
On and off the magnetic path is controlled by turning
the manual nozzle. There are shackles on the top of Magnetic
Lifting Hoist for lifting, a veto slot on the holding
face for holding cylindrical component firmly.
2.2 Specifications
|
Model |
Rated lifting
strength(kgf) |
Cylindrical lifting
strength(kgf) |
Max pull-off strength(kgf) |
L |
B |
H |
R |
Operation temperature(°C)
|
Dead weight(kg) |
|
PMQZQ100 |
100 |
50 |
350 |
62 |
92 |
67 |
126 |
<80 |
3 |
PMQZQ300 |
300 |
150 |
1050 |
92 |
162 |
91 |
155 |
<80 |
10 |
|
PMQZQ600 |
600 |
300 |
2100 |
122 |
232 |
117 |
196 |
<80 |
24 |
PMQZQ1000 |
1000 |
500 |
3500 |
176 |
258 |
163 |
285 |
<80 |
50 |
|
PMQZQ2000 |
2000 |
1000 |
7000 |
234 |
378 |
212 |
426 |
<80 |
125 |
PMQZQ3000 |
3000 |
1500 |
10500 |
286 |
458 |
261 |
521 |
<80 |
220 |
|
PMQZQ6000 |
6000 |
3000 |
21000 |
430 |
600 |
355 |
180 |
<80 |
420 |
|
3. OPERATIONS
3.1
During operations, you should clear away the components
surface such as rust and burr. The center line of lifter
had better overlap with the centerline of component. Then
place the Magnetic Lifting Hoist on the face of component,
turn the nozzle from “-” to “+”
until “holding”. Make sure that the security
key on the handle is automatically locked, and then start
to hoist.
3.2 During
lifting and handing components, overloading is forbidden.
Nobody is allowed to pass through under the component
held by Magnetic Lifter. Components temperature and ambient
temperature shall be lower than 80 ºC. No strong
vibration and impact.
3.3 When
lifting and handling cylindrical components, keeping the
cylindrical surface contacts the Vee Slot of lifter on
two lines, the actual lifting capacity will generally
be 30%-50% of the rated lifting capacity.
3.4 When
lifting and handling operation is finished, press down
the bottom to disengage the security key from the security
pin, then turn the handle “+” to “-”
until “Release”. The lifter is now in the
neutral condition, it can be taken away from the component.
4. Main factors which influence
the lifting capacity of Permanent Magnetic Lifter.
4.1 Influenced
by thickness and surface quality of the component.
Before operation, it is necessary to find out the percentage
of the steel thickness-lifting capacity according to the
component and capacity curve. If its surface roughness
Ra is less than 6.3 um, the lifter surface gap will not
exist, the lifting capacity will be 100%. If the surface
roughness Ra is above 6.3 um or even worse, the lifter
surface gap should be estimated. Find out the percentage
that lifting capacity of the lifter may reach from the
air gap-lifting capacity curve shown in the performance
chart. Combine these two factors and calculating the lifting
capacity that the lifter may reach. The curves are on
the two sides of lifter.
4.2 Influenced
by the composition of steel component.
After measurement, if low-carbon steel component is regarded
as a reference and the coefficient of lifting capacity
is fixed: the coefficient for medium-carbon steel is 0.95;
the coefficient for high-carbon steel is 0.90; the coefficient
for low-alloy steel is 0.75, and the coefficient for cast
iron is 0.50.
5. Maintenance and safety
notice
5.1 While carrying and using permanent
magnetic lifter beware of the bumping and roughness of
surface. So as not to influence its property and life-span.
After using, the lifter had better be protected by oil.
5.2 Please
read the operating instruction carefully and know its
property before using this liter to avoid accident. Please
contact our company for further detail.
5.3 Check
the quality of the handle button frequently. Make sure
that the security key can be moved flexibly and the security
pin can be locked firmly.
5.4 When
Magnetic Lifting Hoist is not in contact with ferromagnetic
material of component, don’t turn the nozzle.
NOTE: Please
read the Operating Instructions carefully before using